2 mm system
Spring-basket plugs, sockets, test leads, probes and shorting plugs in 2 mm
2 mm standard products, 300 V and above
The 2 mm safety system holds the 2 mm articles for higher voltages: the MFK 2028 safety test lead for 600 V and 5 A with a shroud over the contact and the BU 2800 press-in safety socket for 600 V CAT II and 5 A. The lead comes in ten colours and in your length, with your marking on request.
Available in · varies by article
01 Safety system
The safety system covers every article rated at 300 V and above. On the plugs of the MFK 2028 safety test lead an insulating shroud surrounds the 2 mm contact, the cable is double-insulated and has a wear indicator. The BU 2800 press-in safety socket has a glass-fibre reinforced polyamide body and a gold-plated brass contact and sits in an 8.3 mm hole.
For open set-ups up to 30 V AC / 60 V DC there is the 2 mm system, the shrouded range in 4 mm up to 1000 V CAT II is the 4 mm safety system.
02 Test leads
According to its datasheet the MFK 2028 safety test lead is rated for 600 V and 5 A: 0.5 mm² PVC cable, double-insulated with wear indicator, stackable 2 mm spring-basket plugs with a nickel-plated brass and CuBe contact, polyamide insulation, in ten colours and in the length you specify. Its datasheet is available as a PDF.
The MFK 2029 test lead for 30 V AC / 60 V DC is listed in the 2 mm system. Lengths, marking and different plugs per end: test leads made to measure.
| Picture | Cat. no. | Description | Rated current | Rated voltage | Colours | Action |
|---|---|---|---|---|---|---|
| MFK 2028 | 2 mm safety test lead, stackable, with PVC cable 0.5 mm², 600 V 2 mm · nickel-plated | 5 A | 600 V |
| Details (MFK 2028) |
Every article is also available with your marking, your print or in the cable length you need. Values not listed here are available on request.
03 Sockets
The BU 2800 press-in safety socket is rated for 600 V CAT II and 5 A: gold-plated brass contact, PA6 GF15 polyamide body, solder pin Ø 1.9 × 9 mm, mounting hole Ø 8.3 mm. Its datasheet is available as a PDF.
2 mm sockets for 30 V AC / 60 V DC are listed in the 2 mm system.
| Picture | Cat. no. | Description | Connection | Rated current | Rated voltage | Action |
|---|---|---|---|---|---|---|
| BU 2800 | 2 mm safety press-in socket, 600 V 2 mm · gold-plated | Solder pin | 5 A | 600 V, CAT II | Datasheet (2 mm safety press-in socket, 600 V, PDF) Enquire (BU 2800) |
Every article is also available with your marking, your print or in the cable length you need. Values not listed here are available on request.
04 Customisation
Schnepp adapts the articles of the 2 mm safety system to your application: with your marking, printed with your name or logo, or as a safety test lead in your length. For special leads, the values we confirm in the datasheet apply.
To your system, so every part is identified at a glance.
Your name or logo printed on.
Test leads in exactly the length your application needs.
A cable to your specification instead of the standard one.
Plugs, sockets and contact pins to your drawing, built on our bundle-wire and spring-basket technology.
From small batches to volume production, made in Neudenau, Germany.
FAQ
The 2 mm articles rated at 300 V and above: the MFK 2028 safety test lead for 600 V and 5 A and the BU 2800 press-in safety socket for 600 V CAT II and 5 A.
The MFK 2028 is the safety test lead for 600 V, the MFK 2029 in the 2 mm system is rated for 30 V AC / 60 V DC. Both have a double-insulated 0.5 mm² PVC cable with wear indicator, are rated at 5 A, stackable and available in ten colours.
According to its datasheet the BU 2800 press-in safety socket sits in an 8.3 mm hole and is connected by a solder pin Ø 1.9 × 9 mm.
Yes, the datasheets of the MFK 2028 safety test lead and the BU 2800 press-in safety socket are available as PDFs in the table.
Yes, the 4 mm safety system comprises safety test leads, safety plugs, safety sockets, coupler, shorting plug, test probe and clip up to 1000 V CAT II.
Enquiry
Tell us the catalogue number, colour and quantity. For a made-up safety test lead, length, colour and marking are enough.